DEHUMIDIFICATION (DRY)
When the air conditioner is in the dehumidification mode, it doesn't
cool the room.
When you use the air conditioner in the dehumidification mode, you
don't have to use the flexible tube. For maximum dehumidification effi-
ciency leave the rear discharge outlet free to discharge directly into
the room.
G
Remove the flexible tube by grasping it at the attachment point on
the air conditioner and twisting it until you release it from the block-
EG
ing hooks.
Press the ON /OFF push button (A)
er.
G
Select dehumidification mode pressing the push button (B)
lamp (H) lights up
water) will be collected in the internal tank of the air conditioner.
G
To stop the air conditioner press again the ON/OFF push-button.
(A).
WARNING !
The air conditioner may be used as dehumidifier only if the room tem-
perature is above 10 °C. When the room temperature is below 10 °C,
the compressor stops and the dehumidification doesn't occur, while
the fan goes on working.
ATTENTION:
the control causes a compressor starting delay of about three
minutes each time buttons A, B and thermostat D are activated or
when the plug of supply electric cable is took out and in.

SETTING AIR FLOW DIRECTION

To set the air flow direction, seize with both hands one of the deflector
blades and pull towards you

HOW TO DISCHARGE THE WATER TANKS

The air conditioner removes humidity of the air, collecting the conden-
sate into the internal tank. The condensate water can be evacuated
through the external discharge tube located on the rear of the unit.
G
When the internal tank is full, the air conditioner will automatically
stop and the water tank alarm
The tank capacity allows approx. 6 hours operation.
G
Verify the presence of water inside the air conditioner, looking at
the rear external discharge tube.
G
Press the ON /OFF push button to switch off the unit, then unplug
the cable.
G
Position a container under the discharge tube.
G
Grasp the tube removing it from its seat on the rear of the air condi-
tioner
G
Close with the inch the open end of the tube and, tilting it towards
the container, let the condensate water flow.
G
At the end of the operations reinsert the discharge tube into its
place.
Every time you move the unit to another room or when you store it,
discharge also the condensate water of the secondary tank, through
the tube located inside the space for cable winding.
IMPORTANT
At the end of the operation close the tube with its stopper.
WARNING
G
Always switch off the air conditioner before unplugging it from the
power socket.
G
Always unplug the air conditioner before discharging the conden-
sate water collected inside.
4
to start the air condition-
. The humidity of the room (condensate
begins flashing.
,
B
C
Vertical Flow
H
A
D
Horizontal Flow
SECONDARY TANK