Safety fuel handling
CAREFUL!
This fuel is extremely flammable. Do not smoke or bring flame or sparks near fuel.
!IMPORTANT
1. Stop the engine before refueling.
2. Using the wrong oil can lead to fouling of the spark plug, clogging of the exhaust or seizing of the piston
rings.
3. Move at least 3 meters away from the fuel point before starting the engine.
4. Using an improper fuel will cause severe
damage to the internal parts of the engine in a
short time.
CHECKING THE AIR FILTER
Check the air filter to make sure it is clean and
working.
Remove the generator side cover
Open the air filter cover and remove the air
filter element. If necessary, clean or replace
it. Clean the filter element with neutral
solvents, dry it and then soak it in a film of
oil. Remove excess oil by squeezing.
The engine is not allowed to run without an
air filter element, otherwise dirt will enter the
engine through the carburetor and cause
rapid wear.
STARTING THE ENGINE
● It is strictly forbidden to use the generator in indoor
and closed spaces.
1. The knob on the tank cap is turned to the "ON"
position, to allow gasoline access to the carburetor.
Note: When the generator is transported, the fuel
tank switch will be turned to the "OFF" position.
2.Turn the engine switch to the "CHOKE" position.
Note: When the engine is hot or the ambient
temperature is higher, the shock should not be used.
3. Pull the starter handle smoothly until resistance is
felt, then pull steadily. Do not let the starter handle
jerk back toward the engine. Return gently to prevent damage to the handle
or case.
4. After the engine has started, turn the engine switch to the " RUN" position.
6
6. INSTRUCTIONS FOR USE
Valve actuation