opErATIoN

Cleaning, care and maintenance

4.5

Frost protection

f Set the operating selector to frost protection
f
In this position, the temperature controller switches heating on
automatically if the room temperature drops below the frost pro-
tection temperature.
4.6

Automatic

Series CNS-SE
f Set the operating selector to automatic
f
On this setting the appliance heats for 120 minutes in comfort
mode and then switches automatically to the frost protection
function.
Series CNS-UE
f Set the operating selector to automatic
f
If the appliance is connected to an optional control device, you
can use this to operate it. Depending on the setting of the control
device, the appliance heats at certain times of the day in comfort,
ECO or frost protection mode.
If the appliance is not connected to a control device, the appliance
heats in comfort mode.
4.7

Limiting the temperature controller

Using the two pins fitted to the back of the control casing, you
can fix the temperature controller at a certain setting or limit the
temperature setting range.
f Break out the pins.
f
2
1
1 Pin
2 Temperature selector
f To fix the selected temperature, push a pin into the hole
f
opposite.
www.stiebel-eltron.com
.
.
.
1
2
1
1 Pin
2 Temperature selector
f To limit the temperature setting range, set the minimum and
f
maximum values at the temperature selector, and push a pin
for each into the slightly offset hole opposite.
4.8

Shutdown

f Move the switch on the right of the appliance to OFF.
f
5.
Cleaning, care and maintenance
CAUTION Burns
Never spray cleaning spray into the air slot.
Ensure that no moisture can enter the appliance.
f If a pale brownish discolouration appears on the appliance
f
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning
products.
f Avoid abrasive or corrosive cleaning products.
f
Note
As part of regular maintenance, we recommend also
having the control components checked. The safety and
control components should be checked by a contractor
no more than ten years after commissioning.
6.

What to do if...

... the appliance does not heat up:
f Check the temperature set at the appliance and the MCB/fuse
f
in your fuse box.
The appliance has a safety temperature controller that shuts the
appliance down if it overheats. After the cause has been removed
(for example air outlet or inlet apertures covered) and the appli-
ance has cooled down for a few minutes, operation starts again.
If you cannot remedy the fault, notify your qualified contractor.