EMC immunity
EMC
Dimensions
Weight
Materials
Terminals
(Screw terminals)
Cable entry
Operating elements
DIP switches
Factory default
Display elements in the LC display
Display
Display range
Process value status
Up date
manuals search engine
10. Technical data
Interferance immunity and emission according to
EN 61 326-1
100 x 100 x 61 mm; see chapter 4.1
Approx. 0.6 kg
Housing in die cast aluminium, surface powder
sintered
Wall/stand pipe brackets: St. St. 1.4301
Tension strip: St. St. 1.4301
≤ 2.5 mm²
Bus cable:
PG 13.5 cable gland (for 5...9 mm cable diameter) or
NPT 1/2 " or
Field bus connector (WDM) 150 mm
See chapter 6.2
1. Process value of sensor to the address 4
7 digit LC display,
7.5 mm character height; see chapter 6.2
See chapter 6.2
See chapter 6.2
< 1 / s
37