• Briefly press the set-up button, to select the next value. Check the flash signal.
Once the desired value is reached (for 40% the red LED will flash 1 x long and 2 x short), switch off the drive control
unit. This concludes the programming, the value is saved.
If you wish to adjust other settings (e.g. low-voltage protection), then proceed as described above.
Release the set-up button exactly when the green LED flashes for the corresponding function to be
adjusted (or the corresponding beep tone is heard); an exact description of the individual functions is
given further below.
Then press the set-up button shortly as often as required until the red LED flashes correspondingly for
the desired setting value.
If the drive control unit is switched off, the current setting and/or value will be saved.
The settings/values with the grey background are the factory settings made by the manufacturer.
#
Green LED blinks...
Function
(+ beep)
1
1x short
Drive function
2
2x short
Handbrake
3
3x short
Undervoltage protection off
4
4x short
Start mode
5
1x long
Maximum brake power
6
1x long, 1x short
Max. speed for driving
backwards
7
1x long, 2x short
Minimum brake power
8
1x long, 3x short
Neutral range
9
1x long, 4x short
Timing
10 2x long
Motor type
11 2x long, 1x short
Excess temp. protection +95°C
• Function #1, green LED flashes 1x short: Drive function
In this settings menu the drive control unit can be switched between "forwards/brake" and "forwards/brake/reverse"
(factory setting).
• Function #2, green LED flashes 2x short: Handbrake
The handbrake function stops the vehicle from rolling when it is on an uneven surface or slope. The higher the set
value of the handbrake function, the less the vehicle rolls when it is resting on a slope. A standard electric motor - at
rest - has a certain amount of braking strength due to the magnets it contains - a brushless electric motor, however,
does not.
Settable values are 0%, 5%, 10% (factory setting) 15%, 20%, 25%, 30%, 40%.
1x short
2x short
Forward/brake Forward/brake/
backward
0
5%
2.6V/cell
Soft
Normal
25%
50%
25%
50%
= handbrake
0%
6%
9%
0.00
3.75
Brushless
Off
Red LED blinks...
3x short
4x short
1x long
10%
15%
20%
2.8V/cell
3.0V/cell
3.2V/cell 3.4V/cell
Fast
Very fast
75%
100%
75%
100%
20%
40%
12%
7.50
11.25
15.00
1x long,
1x long,
1x long,
1x short
2x short
3x short
25%
30%
40%
18.75
22.50
26.25
41