Heater
Sauna room
Model and
dimensions
Cubic vol.
Width:
480mm
Depth:
310mm
Height:
540mm
Weight:
11kg
Stones:
max. 20kg
kW
Min.
m³
BC45
4,5
3
BC60
6,0
5
BC80
8,0
7
Bc90
9,0
8
Table 2: Installation details
Figure 6: Safety distances (all dimensions in millimeters)
Fastening the Heater on a Wall
See figure 7.
5. Remove both cardboard covers before installation.
6. Fasten the wall-mounting rack on the wall by using the screws which come with the rack. NOTE!
There must be a support, e.g. a board, behind the panel, so that the fastening screws can be screwed into a
Electrical connections
400 V 3N~
Height
Connecting cable
See fig. 8. The measurements apply to the connecting cable only!
Max.
Min.
Mm²
m
mm
6
1900
5 x 1,5
8
1900
5 x 1,5
12
1900
5 x 2,5
14
1900
5 x 2,5
230V 1N~
Fuse
Connecting cable
A
Mm²
3 x 10
3 x 2,5
3 x 10
3 x 2,5
3 x 16
3 x 6
3 x 16
3 x 10
Fuse
A
1 x 20
1 x 35
1 x 35
1 x 50