OPERATION

Appliance description

3.
Appliance description
This appliance has been designed as a booster heater and is par-
ticularly suitable for bathrooms, as well as drying and warm-
ing bathrobes and towels. You can place your towels at various
heights.
The appliance heats the room through natural convection and
radiated warmth. The integral room thermostat keeps the room
at the set temperature. For this, it is important that the appliance's
heating output matches the room's heat demand. This only applies
if no towels or bathrobes are hung on the appliance.
The appliance is ready for operation when it has been fixed to the
wall and plugged into the mains.
You can operate the appliance within a DHW/central heating sys-
tem. Even when the central heating is off, the appliance is oper-
ated via an integral electric direct heater rod.
BHE 175 T Classic: this appliance has a rapid heater with fan,
which you can switch on for a maximum of 2 hours.
4.
Operation
4.1

User interface description

1
8
7
5
6
1 ON indicator
2 Boost function indicator
3 Timer for boost function
4 Pushbutton for boost function
5 ON/OFF switch for the user interface
6 Heat indicator
7 Frost protection setting range
8 Temperature selector
16
| BHE Classic
2
3
1/2 h
1 h
1/4 h
2 h
4
4.2

Operation as an electrical room heater

4.2.1 Switching the appliance on

f Push the ON/OFF switch for the user interface.
f
The ON indicator lights up.
f Set the required room temperature with the temperature se-
f
lector. You can choose between 6 °C and 30 °C.
The heat indicator lights up when the appliance starts to heat. The
heat indicator goes off when the temperature set at the temper-
ature selector is reached.
Note
If several appliances are installed in one room, a different
temperature can be set at each one.
Note
To avoid excessive power consumption when windows
are open, stop the appliance while venting.

4.2.2 Boost function

When the boost function is enabled, the appliance heats for a
maximum of two hours at full power.
BHE 175 T Classic: When the boost function is enabled, the
appliance heats for a maximum of two hours at full power and
with the rapid heater on.
Enable
f Switch the appliance on.
f
f Press the boost function pushbutton.
f
The boost function indicator lights up.
f Use the boost function timer to set the required duration.
f
The appliance enables the boost function for the preselected pe-
riod.
At the end of the preselected period, the appliance returns to
standard operation with the temperature selector. The boost func-
tion indicator goes off.
Note
If you switch off the appliance while the boost function
is enabled, the preselected period for the boost function
continues when the appliance is switched back on.
Disable
f Press the boost function pushbutton again.
f
The boost function indicator goes off. The appliance returns to
normal operation controlled by the temperature selector.
4.3

Frost protection

The appliance has a frost protection function to ensure that the
room temperature does not fall below 6 °C if the property is empty
for a prolonged period.
f To enable the frost protection function, leave the appliance
f
on and turn the temperature selector to the frost protection
setting.