Installing The Grille - Mitsubishi Electric PLFY-WP32VBM Installationshandbuch

Air-conditioners for building application indoor unit plfy-wp vbm-e serie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Installing the grille

Fig
Fig
Fig
Fig
4-directional
1 pattern:
Initial setting
Blowout
direction
patterns
2-directional
6 pattern:
2 air outlet fully closed
Blowout
direction
patterns
Table 1
-
-2
-
-
3-directional
4 pattern:
1 air outlet fully closed
Chec ing the contents (Fig
This kit contains this manual and the following parts.
Accessory name
1
Grille
2
Screw with captive washer
3
Gauge
4
Fastener
5
Screw
6
Screw
7
i-see sensor corner panel
2 Preparing to attach the grille (Fig
With the gauge 3 supplied with this kit, ad ust and check the positioning of the unit
relative to the ceiling. If the unit is not properly positioned relative to the ceiling, it
may allow air leaks or cause condensation to collect.
Make sure that the opening in the ceiling is within the following tolerances:
6 × 6 - 91 × 91
Make sure that A is performed within 17-22 mm. Damage could result by failing to
adhere to this range.
A Main unit
B Ceiling
C Gauge 3 (inserted into the unit)
D Ceiling opening dimensions
2
Re o ing the inta e grille (Fig
Slide the levers in the direction indicated by the arrow 1 to open the intake grille.
Unlatch the hook that secures the grille.
* Do not unlatch the hook for the intake grille.
With the intake grille in the "open" position, remove the hinge of the intake grille
from the grille as indicated by the arrow 2.
2 2 Re o ing the corner panel (Fig
Remove the screw from the corner of the corner panel. Slide the corner panel as
indicated by the arrow 1 to remove the corner panel.
Fig -
-
A Intake grille
B Grille
C Intake grille levers
D Grille hook
E Hole for the grille's hook
F Corner panel
G Screw
H Detail
Selection o the air outlets
For this grille the discharge direction is available in 11 patterns. Also, by setting the
remote controller to the appropriate settings, you can ad ust the air ow and speed.
Select the required settings from the Table 1 according to the location in which you
want to install the unit.
1) Decide on the discharge direction pattern.
2) Be sure to set the remote controller to the appropriate settings, according to the
number of air outlets and the height of the ceiling on which the unit will be installed.
Note:
For - and 2-directional please use the air outlet shutter plate (option)
- )
Q'ty
Remark
1
95 × 95 (mm)
4
M5 × . × 25
1
(Divided into four parts)
3
4
4 ×
1
4 × 12
1
for PLP-6BAE
-2)
- )
- )

Werbung