16. Software update | 17. Other functions
16. Software update
Software can be updated using microSDHC memory card only.
SOFTWARE MAY BE UPDATED BY AN AUTHORIZED PERSON ONLY.
TAKE SPECIAL PRECAUTIONS TO AVOID RISK OF ELECTRIC SHOCK!
Disconnect controller mains supply to update the software. Insert card into
the memory card slot. New software is saved in two *.pfc files: control panel
program file and module A program file. New software must be copied to the
root directory of the memory card. Connect mains supply and select:
General settings > Software update and update software in module A
and controller panel in that order.
Leader in pellet boilers
17. Other functions
17.1 Power failure
In case of a power failure, the controller will restore the operating mode
selected before power failure.
17.2 Protection against freezing
If the boiler temperature is below 5°C, the boiler pump is activated to force
circulation of the boiler water. If the temperature does not increase, the burner
is activated.
THIS FUNCTION MAY NOT BE THE SOLE PROTECTION AGAINST
FREEZING. USE OTHER MEANS OF PROTECTION.
THE MANUFACTURER IS NOT LIABLE FOR ANY RESULTING
DAMAGE.
17.3 Protection against seizure
The controller protects CH, DHW and mixing valve pump against seizure by
activating the pumps periodically (every 167 hours) for several seconds. It
protects the pumps against seizure due to the scale accumulation. Keep the
controller power supply connected even if the boiler is not in use. The function is
also enabled with the controller in „Boiler OFF" mode.
17.4 Replacing mains fuse
Mains fuse is installed inside the controller enclosure. Mains fuse must be
replaced by a qualified person only after disconnecting the mains supply. Use
delay action fuse, porcelain type, 5x20 mm, 6.3 A rating.
17.5 Replacing control panel
Replacing the control panel is not recommended, since the program stored in
the control panel must be compatible with the control module program.
Platinum Bio ecoMAX 860P User Manual – EN 09.17