Every 500 operating hours, at least
 Have the maintenance of the device
performed by the customer service.
 Oil change.
Oil change
Note:
See "Specifications" for oil volume and
type.
 Unscrew the fastening screws of the
device hood; remove the device hood.
 Remove the lid of the oil container.
 Tilt the appliance forward.
 Drain the oil in a collection basin.
 Fill in new oil slowly; air bubbles should
go out.
 Attach the lid of the oil container.
 Fasten the device hood.

Troubleshooting

DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
Prior to all work on the appliance, switch off
the appliance and pull the power plug.
Get the electrical components checked and
repaired only by authorised customer ser-
vice persons.
Contact an authorised customer service
person in case of problems not mentioned
in this chapter or if you are in doubt or when
you have been explicitly asked to do so.
Appliance is not running
 Check connection cable for damages.
 Check the supply voltage.
 Call Customer Service in case of elec-
trical defects.
Pressure does not build up in the
 Set nozzle to "High pressure".
 Clean the nozzle.
 Replace the nozzle.
 Deaerate the appliance (see "Start-up")
 Check water supply level (refer to tech-
nical data).
24
annually
appliance
 Clean the sieve in the water connection.
 Check all inlet pipes to the pump.
 Contact Customer Service if needed.
3 drops per minute are permitted and can
come out from the lower side of the appli-
ance. Call Customer Service if there is
heavy leakage.
 With stronger leak, have device
checked by customer service.
Pump is vibrating
 Check suction pipes for water and de-
tergent and ensure that they are leak-
proof.
 Close dosing valve for detergent to op-
erate the machine without detergent.
 Deaerate the appliance (see "Start-up")
 Contact Customer Service if needed.
Detergent is not getting sucked in
 Set nozzle to "CHEM".
 Check/ clean detergent suction hose
with filter.
 Open or check/clean detergent dosing
valve.
 Contact Customer Service if needed.
Accessories and Spare Parts
Only use original accessories and spare
parts, they ensure the safe and trouble-free
operation of the device.
For information about accessories and
spare parts, please visit www.kaerch-
er.com.
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.