9. Care and maintenance

9.1 Operations after fastening
Withdraw the axle (7) again while releasing the detent
(40). Remove the revolving magazine (1).
en
Holding the drum assy (2) over a soft surface e.g. a cloth,
and working from the sealing cap end, push out the bar-
rels (13) firmly using the grip end of the extractor. Push
out two barrels (13) on each side of the screw and then
rotate the drum assy (2) through 180° before pushing
out the remaining two barrels. In doing so, the used seal-
ing caps are also removed.
Eject spent cartridge cases using the ejector.
After reinserting the barrels (13) in the revolving maga-
zine, the next loading operation can be begin immedi-
ately.