Note; Up Time - Vestamatic Rolltec Plus Montageanleitung Und Bedienungsanleitung

G/s 500
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

83100311 H1.qxd
20.06.01

Note

The Vestamatic Rolltec Plus G/S 500 roller shutter control is delivered
with the following manufacturer's default up and down times (day
function is activated):
· Daily up time
– 0ß6:0ß0 p.m.
· Daily down time – 2ß0:0ß0 a.m.
Please find the manufacturer's default DIP switch settings in the
tables on page 58 and page 61.
Important: It is important to push the selector switch "automatic/
manual-mode" to automatic mode (A), in order to be
able to perform the following programming steps.
Check the current setting. If the selector switch is not set
on (A), correct the setting by pushing it all the way to the
left until you hear the "click".
09:17
Seite 51
Basic functions
- 49 -
G
Basic functions
By operating the combination of set and up button you can set the up
time.
Setting the up time can be performed as follows:
1. Press the set button first and keep it pressed, then:
A. Press the up button and keep it pressed to fast forward the

up time.

B. Shortly tap the up button to slow forward the up time.
or
2. Press the up button first and keep it pressed, then:
A. Press the set button and keep it pressed to fast reverse the up
time.
B. Shortly tap the set button to slow reverse the up time.
The display will now indicate the set value. Once the programming
buttons are no longer operated, the display will indicate the current
time again. Tapping the up button will check the set value and the dis-
play will again indicate the previously set up time. After approx. 2 sec-
onds, the display will indicate the current time again.
- 50 -
G
Up time