5.3. Cooling unit control (CUC)

The electronic checks the function after every
defrosting period (every 24 hours) by measuring the
evaporator temperature drop. If it registers a problem
the refrigerator will shut down and the LEDs of the
interior light will begin to flash continously. If this
happens you should check whether the refrgerator has
been overloaded, that the door was properly closed,
that the cooling unit ventilation is correct and that the
refrigerator is levelled. After checking, unplug the
refrigerator at least for 10 seconds and plug in again.
This resets the unit and it will function again. If the
countinous flashing comes back there is a problem
and you should then contact Dometic service.
6. Useful suggestion
Do not overfill the appliance. Put warm foods and drinks
in the appliance only when they have cooled down to
room temperature. It is advisable to leave some space
between the products in the cabinet to ensure efficient
and even cooling. If the shelves are packed too tightly
there may be unacceptable temperature variations.
7. Defrosting, cleaning and
maintenance
Frost will gradually form on the cooling fins and it must
not be allowed to become too thick since it restricts
the cooling.
The miniCool is fitted with a fully automatic, electronic
temperature regulator.
The frost will melt and the defrost water will run through
the drain tube from the drip channel into an evaporating
vessel located at the bottom rear of the refrigerator. (Fig
7) The defrost water will evaporate automatically into
the circulating air and the vessel will not need emptying.
To switch off the unit, disconnect the refrigerator from
the electricity supply and leave the cabinet door open.
After defrosting the cabinet interior should be wiped
out with a clean, damp cloth.

7.1. Automatic defrost function

The first defrosting phase commences 39 hours after
the start and lasts for two hours.
After this, the device operates for 22 hours at a time,
followed by a defrosting period of 2 hours.

8. Interior light

Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door is
opened.
Figure 7.
Two sensors (B) control whether the door is open
or not and the LEDs will work accordingly.
B
B

9. Reversing the door hang

Disconnect the mains.
Lay the appliance on its side.
Remowe the 6 screws (1) from the foot frame
and also the screw in the mid of the air grill and
take the frame down.
Put the fridge on a desk to ease the work.
Open the door and snap out the fixing tab (2) of
the upper hinge pin by the help of screwdriver
and push out the pin. (fig. 10.)
Remove the door and the hinge washer.
Remove the bottom hinge pin (3) and the upper
and lower hinge plug (4) in the same way as in
case of the upper hinge pin.
Snap in the lower hinge pin (3) to the desired side.
Put back the door and the hinge washer and
snap in the upper hinge pin (2).
Snap in the 2 hinge plugs (4) too.
Put the foot frame back and fit it with the 7 screws
Figure 10.
A
A
Figure 8.
(Fig. 9-10.)
Figure 9.