4. Maintenance &
Troubleshooting
Message
Check connection
or Check battery
Interruption: Please defrost
device slowly
Interruption: Surroundings too
warm
Please contact service
Please check exhaust hose
Please change fuel cartridge
Please check fuel cartridge
connector
Please refill service fluid
Please check battery voltage
Automatic restart
4.3

Problems and Solution

Errors with text message
At the remote control the red and yellow light indicate a
system error. The remote control additionally shows a
detailed error message.
Press the reset button on the control panel AFTER the
problem has been solved.
Please contact our sales partner where you have
bought the product if you can not fix the error yourself.
Solution
Check remote control connection – proper socket on
the EFOY Pro is marked „Remote Control".
The unit is frozen. Let stand at room temperature for
approx. 24 hours before operating.
Ambient temperature is too high. The unit starts again
as soon as it has cooled down.
System periphery error. Please contact the SFC partner
where you have bought the product if the problem
remains after a restart.
Check that the exhaust hose has been properly
connected and arrange it so that condensation cannot
form.
Insert a new fuel cartridge. Check connection and
screw cartridge on tightly.
Check fuel cartridge connection and screw cartridge on
tightly. Check cartridge hose for kinks. Check hose and
connection for dirt.
Add service fluid.
Check battery voltage – is either too low or too high. If
too low, use an external battery charger to recharge.
Unit is restarting automatically - please wait.