Follow these procedures before installing the Multi-Pathing Driver:
Change the bootloader entry in /boot/grub/menu.lst to use
a
the original default initrd - without mpp support.
Uninstall current RDAC Multipath driver - run "make
b
uninstall" from the linuxrdac source directory; the default
linuxrdac directory is
/opt/dell/mdstoragemanager/Linuxrdac-
xx.xx.xx.xx.
DO NOT REBOOT. Rebooting may cause DATA corruption.
c
6 Update the version of MD Storage Manager installed on your host server
using the Resource CD. Refer to your Installation Guide for detailed
information.
7 Using MD Storage Manager, update the MD3000 RAID controller
firmware and NVSRAM by selecting Support→Download Firmware→
Download RAID Controller Module Firmware. Select appropriate file
locations for both the Firmware as well as NVSRAM update packages and
click Transfer. When a successful download confirmation message is
displayed, the firmware and NVSRAM have been updated.
8 Repeat steps 1 through 6 for each host server attached to your RAID
storage enclosure.
9 Follow steps 1 through 3 of the previous section (Updating your MD3000
RAID Controller Module Firmware from a Management Station) to
update the software on all the management stations connected to the
MD3000.
Preparing an MD1000 Attached to a PERC Adapter
before Connecting it to the MD3000
If you have an MD1000 attached to a PERC Adapter to use with your
MD3000, the following steps MUST be performed before attaching it to a
MD3000.
Upgrade the SATA Physical Disk firmware for all SATA physical disks in
the MD1000 following the procedure described below
Prepare the MD1000 as described in the following section, before
attaching it to the MD3000.
Updating to Support SATA II Disks
7