Setting up the faytech Touch software
setting, try it with the Draw Test application under the Tools tab.
On the far right of the mouse icon, there is an
options are available for the faytech display in this submenu:
is the function to check to enable the driver to
Enable Constant Touch:
l
determine if the most recent touched position is the same as the previously
touched point. If the difference is smaller than the defined area, the driver
does not generate any mouse movement which helps reduce system load.
If the touch screen is touched for a specified time,
Enable Auto Right Click:
l
the driver will generate a mouse right button click if this function is enabled.
Be careful! If you don't check this box, the touch function will
Enable Touch:
l
not work!
A software filter exists inside the driver to filter
Enable Cursor Stablization:
l
some noise to stabilize and smooth the touch points. When activated, the
user will experience a more stable cur
button. The following
Option
sor.
46
faytech Ltd. 2009
C
Setting up the faytech Touch software
You can adjust the parameter for the
criterion to judge if the most recent touched point is the same as the previously
touched point. If the difference between the two points is within this area, it will be
recognized as the same touch point and the driver does not generate a new
mouse event for this touch point.
You can adjust the
Auto Right Click Time
touched and held for this period of time, the driver generates a right mouse click.
tab
3.Tools
:
You can adjust the faytech touch panel calibration with the functions called
,
Points Calibration Clear and Calibrate Linearization
Start by performing the 4 points calibration. By using the application drawing
test, you can test the touch panel to determine if further setting changes are
desirable.
When you press the 4 Points Calibration button, the surface of the monitor
shows the following image:
Touch and hold each of the blinking X symbols in the calibration window until it
stops blinking to make sure that the utility can gather enough data for
computation. In addition, a progress bar is shown at the bottom of the window
function. This is a
Constant Touch Area
function. If the touch screen is
,
and
Draw Test.
Press blinking X symbol until stop blinking
47