Instructions for use for the user
The Auto Refill Set (CP-RC-AF) allows for a fixed water connection,
making automatic filling of the evaporator tank possible.
ATTENTION!
Damage to the evaporator
Sea water, hard water, chlorinated water, herbs, essences or fragrances can
damage the sauna heater.
● Only fill the evaporator tank with tap water.
● Do not put herbs, essences or fragrances directly into the evaporator tank,
but only into the ceramic bowl over the evaporator.
● Descale the evaporator regularly (see 7.3. on page 22).
Filling the evaporator
CAUTION!
Risk of scalding
If you pour water into the hot evaporator tank, hot steam is created.
● NEVER pour water into the hot evaporator tank.
● Check and fill the evaporator tank each time before starting combi
mode.
● If the overheating protection has switched off the heating of the
evaporator or if your sauna control unit reports a lack of water, al-
low the evaporator to cool down BEFORE you pour water into the
evaporator tank.
CAUTION!
Risk of scalding
If the evaporator tank is too full, boiling water will spray out of the evapo-
rator tank.
● Only fill the evaporator tank up to the maximum mark.
1. Remove the ceramic bowl 1 and the steam funnel 2.
2. Place a receptacle (at least 5 litres) under the ball valve at the bottom of
the evaporator.
3. Turn the ball valve to the left, until the remaining water flows out.
4. When the evaporator tank 3 is empty, close the ball valve.
p. 20/26