Installation instructions, only for experts
4. Installation and connection
Observe the following points when installing and connecting the auxiliary evapo-
rator:
WARNING!
Risk of electric shock
● The auxiliary evaporator must only be installed and connected when
the power supply is disconnected.
● The electrical connection may only be performed by a qualified electrician or
similarly qualified person.
● An all-pole disconnecting device with full cut-off must be fitted on-site in ac-
cordance with overvoltage category III.
● The auxiliary evaporator R is intended for installation on the sauna wall.
● Observe the minimum distances specified in 4.2 during installation.
4.1. Installation location
Install the evaporator at a suitable location on the cabin wall or on your Concept
R combi sauna heater, and observe the minimum safety distances when doing so.
4.2. Safety distances
Observe the minimum safety distances specified in Fig. 1 (page 12).
4.3. Installation on the cabin wall
Observe Fig. 1, Fig. 2, Fig. 3 and Fig. 4 (page 12, 13).
1. Attach the mounting rail 1 to the wall so it is level with the supplied wood
screws 2 . Observe the minimum distances for the auxiliary evaporator
shown in Fig. 1.
2. Mount the evaporator 3 on the mounting rail starting at the top. Make sure
that the evaporator is flush against the wall.
3. Secure the evaporator 3 using the supplied screws 4 on the mounting rail 1 .
p. 10/26