R 05/07
Error Designation Possible Causes and Their Correction
1, 2, 3, 4, 5, 6
7
10, 11, 12
20
21
22 to 27
32
33, 34, 35, 36
37
38
39
STG Hand-Held Terminal PRO
(5)J31069-D0126-U001-A6-7418
S Reader device fails to send start protocol.
S Is read head screwed on?
S Does the read head match the protocol setting? (See
menu: Extras/COMMUNICATION.)
S Batteries in the reader device are dead. (The batteries may
be defective.)
S Internal program error
Interface defective
Reader device doesn't answer at all or sends an incorrect an-
swer (MDS D1xx/MDS F4xx).
S Reader device doesn't answer.
S Check parameters in the Extras/COMMUNICATION menu.
With SIM mode, "Interface" and "Protocol" must both be set
to SIM.
S Batteries in the reader device are empty. (The batteries
may be defective.)
Reader device doesn't answer at all or sends an incorrect
answer.
S Internal program error (MDS D1xx)
S Reader device sends the wrong answer.
S MDS is not personalized with the MOBY key.
S Internal program error (MDS D1xx/MDS F4xx)
Illegal request, internal program error
S Check contact to read head.
S Read device doesn't answer (MDS E6xx)
Internal program error
S Exit STG program, and start again.
S Read/write error (MDS F4xx)
S Read head gives you an error message.
S Read head is faulty.
S CRC error of MDS. Communication error to MDS. MDS is
located on the boundary.
S MDS has a defect.
S Internal program error
Specified block is write-protected.
Several MDSs are in the field.
S Internal program error (MDS D1xx)
Error Messages