Table 1-2. LCD Status Messages
Code
Text
N/A
SYSTEM NAME
E1000
FAILSAFE,
Call Support
E1118
CPU Temp
Interface
E1211
ROMB Batt
E1625
PS AC Current
Causes
A 62-character string that
can be defined by the user
in the System Setup
program.
The SYSTEM NAME
displays under the
following conditions:
• The system
is powered on.
• The power is off
and active errors
are displayed.
Check the system event
log for critical failure
events.
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Power source is out
of acceptable range.
Corrective Actions
This message is for
information only.
You can change the
system ID and name
in the System Setup
program. See "Using the
System Setup Program"
in the Hardware Owner's
Manual.
See "Getting Help" in
the Hardware Owner's
Manual.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" in the Hardware
Owner's Manual.
Reseat the RAID battery
connector. See the "RAID
Battery" and see
"Troubleshooting System
Cooling Problems" in
the Hardware Owner's
Manual.
Check the AC power
source.
Information Update