Configuration
Switching time
The switching time can be set individually.
◆
If the switching time is set to 0, the
◆
selected output remains activated until the
other output is selected.
If the switching time is set to a value greater
◆
than 0, the relay only switches to green for the
duration of the switching time.
Condition
You can configure whether the output should
◆
be restored when the decoder is started.
Connection
The last selected output connection is saved
◆
here.
Outputs
Example of continuous operation
Switching time is 0
◆
The green command on the control panel
◆
switches the relay to the green output.
The relay remains green until the control
◆
panel switches back to red.
Example switching pulse
Switching time is 10
◆
The green command on the control panel
◆
switches the relay to the green output.
After 10 seconds, the relay
◆
automatically switches back to
output red.
Careful
The decoder only restores the last selected
◆
position if the switching time is set to 0.