Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher HD 5/12 C Bedienungsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für HD 5/12 C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
Mains connection
Voltage
Type of current
Connected load
Supply fuse (delayed-action, char. C)
Max. tolerable mains impedance
Extension cable 30 m
Water connection
Supply temperature max.
Supply volume min.
Supply hose – minimum length
Supply hose – minimum diameter
Suction height from an open container
20 °C
Supply pressure max.
Performance data
Operating pressure
Max. operating overpressure
(safety valve)
Flow rate
Detergent intake
Recoil force of the handgun
Sound emission
Sound pressure level
(EN 60704-1)
Garanted sound pressure level
(2000/14/EC)
Vibrations of unit / total of vibration (ISO 5349)
Handheld gun
Spray lance
Dimensions
Length
Width (CX)
Height
Weight without accessories
Weight witouth accessories, CX
Oil quantity, pump
Oil type, pump
22
HD 5/12 C
1.514-105
AU
V
240
Hz
1~50
kW
2,3
A
10
mm
2,5
2
°C
60
l/h (l/min)
600 (10)
m
7,5
inches
3/4
m
0,5
MPa (bar)
1 (10)
MPa (bar) 11,5 (115)
MPa (bar) 13,5 (135)
l/h (l/min)
510 (8,5)
l/h (l/min)
0 – 35
(0 – 0,6)
N
21
dB (A)
74
dB (A)
89
m/s²
2,5
m/s²
1,8
mm
360
mm
375 (400)
mm
925
kg
22
kg
l
0,35
SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40
HD 6/13 C
HD 6/13 C
1.514-201
1.514-204
1.514-203
1.514-251
HD 6/13 CX
1.514-601
1.514-651
EU
KAP, 50Hz
230
220 – 230
1~50
1~50
2,7
2,7
16
16
(0.346
+ j 0.216)
2,5
2,5
60
60
700 (11,7)
700 (11,7)
7,5
7,5
3/4
3/4
0,5
0,5
1 (10)
1 (10)
13 (130)
12,5 (125)
14,5 (145)
15 (150)
560 (9,3)
570 (9,5)
0 – 35
0 – 35
(0 – 0,6)
(0 – 0,6)
25
25
75
75
89
89
1,7
1,7
1,7
1,7
360
360
375 (400)
375 (400)
925
925
23
23
28
0,35
0,35
HD 6/13 C
1.514-205
KAP, 60Hz
220 – 230
1~60
2,7
16
2,5
60
700 (11,7)
7,5
3/4
0,5
1 (10)
12,5 (125)
15 (150)
570 (9,5)
0 – 35
(0 – 0,6)
25
75
89
1,7
1,7
360
375 (400)
925
23
0,35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis