Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanical Fastening; Electrical Connection; Connection Example, Roltop/D+ 868 230 V/50 Hz - Nice Elero Roltop/D+ 868/915 Betriebs- Und Montageanleitung

Rollladenantrieb
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Mechanical fastening

►Do not kink, shorten or extend the aerial.
►Do not undercut the minimum distance of 15 cm between
two radio drives.
5.1
Mechanical fastening
Important preliminary consideration:
The working space around the built-in drive is usually very
small. Therefore, before the mechanical installation provide
an overview of the implementation of the electrical connec-
tion (see Section 5.2) and make any necessary changes
right away.
NOTICE
Damage to the electrical wiring by squeezing or tensile
loading.
►Route all electrical cables so that they are not subjected
to crushing or tensile load.
►Note the bending radius of the cables (at least 50 mm).
►Lay the connection cable in a loop downwards to prevent
water running into the drive.
Damage to the drive by the action of impact forces.
►Insert the drive into the shaft, never thrust the drive into
the shaft or smash onto the drive!
►Never allow the drive to fall!
Damage or destruction of the drive by drilling.
►Never drill into the drive!
Important
Attach the RolTop /D + 868 only at the intended fasteners.
Permanently installed control devices shall be clearly dis-
played.
• The curtain must be fastened to the winding shaft.
• The profile tube must have enough distance to the motor
tube.
• Look for an axial clearance (1-2 mm).
Installation in profile tubes
Ⓐ I nsert the drive with a suitable adapt-
er and traction ring into the profile
tube.
Lay the motor cable protected in or-
der to prevent damage by the driven
component.
Ⓑ S ecure the counter bearings against
axial displacement, e.g. screw shaft
spider or rivet.
Secure drive in axial storage!
Ⓒ S ecure hanging on the shaft!
5.2

Electrical connection

WARNING
Danger to life due to faulty electrical connection.
Electric shock possible.
►Before commissioning check the correct connection of
the PE conductor.
NOTICE
Damage to the RolTop /D + 868 by faulty electrical connec-
tion
►Before commissioning check the correct connection of
the PE conductor.
4 | EN
Damage or destruction of RolTop /D + 868 by the penetra-
tion of moisture
►For units with protection class IP 44, the customer con-
Damage to the Venetian blind from incorrect running direc-
tion
►The assignment of the running direction UP/DOWN with
Adjustment of the end position at the drive.
►Any adjustment of the end positions that occurs indicates
Important
All applicable standards and provisions must be observed
for the electrical installation.
When connecting the drive to a control, the operating
instructions of the control must be observed.
For electric connection no transmission and retransmission
of the access line or connector is required as a rule.
Depending on the mounting plate and/or adapter plate
used it is necessary in particular with the RolTop/D+ 868 to
remove this screwed plate before a cable exchange.
Connection only in free of tension status, in addition
drive line without tension
1 Using a suitable screwdriver, press out the lock of the
2 Disconnect the plug.
3 Insert connector until the latch engages.
Removal and insertion of the device plug
Delivery status
A
B
Fig. 4 Removal and insertion of the device plug
5.3
Connection example,
RolTop/D+ 868 230 V/50 Hz
C
© elero GmbH
nection of the cable ends or connector (cable bushing)
must also be carried out in accordance with protection
class IP 44.
an elero radio transmitter must be reviewed after teach-
ing.
an electrical connection error. Readjustment of the end
positions is not sufficient in this case, since the end posi-
tions are adjusted often. In this case, the drive needs to
be replaced and the cause removed.
device connector to the line.
Remove plug
2
Insert plug
3
1
Inhaltsverzeichnis
loading

Inhaltsverzeichnis