Overcurrent Protection Prompt: When using a 220V/50Hz
●
power supply, if the input current exceeds 20A and remains for
5 seconds, an overcurrent protection alarm will be triggered.
When using a 110V/60Hz power supply, if the input current
exceeds 13A and remains for 5 seconds, an overcurrent
protection alarm will be triggered. Stop using the device,
restart the charging process. If the overcurrent protection
alarm persists, do not continue using the device and contact
our after-sales service (Non-standard detection function).
●
Output Overvoltage Prompt: When the charging voltage
exceeds 19.0V, an output overvoltage alarm will be triggered.
Stop charging and restart the charging process. If the output
overvoltage alarm persists after restarting, do not continue
using the device and contact our after-sales service.
Overcurrent Warning: In programmable power supply mode,
●
an overcurrent alarm will be triggered if the current exceeds
125A. In fast charging mode, the alarm will trigger if the current
exceeds 105A. Charging will stop, and the battery should be
checked for any issues. If charging is restarted and the
overcurrent warning persists, please stop using the device and
contact our after-sales service team.
Undervoltage Protection
Overcurrent Protection
Excessive Output Voltage