Reverse Polarity Connection Prompt: Please remove the
battery clamps and ensure they are properly connected.
●
Emergency Stop Prompt:If the "Emergency Stop" prompt
appears, it means the emergency stop switch has been
pressed, triggering the alarm. Turning the emergency stop
switch clockwise will release the alarm.
●
AC Overvoltage Warning: When using a 220V/50Hz power
supply, an overvoltage alarm will be triggered if the voltage
exceeds 275V. When using a 110V/60Hz power supply, an
overvoltage alarm will be triggered if the voltage exceeds
132V. Once the voltage returns to normal, the alarm will
automatically reset.
●
AC Undervoltage Prompt: When using a 220V/50Hz power
supply, the voltage below 165V triggers an alarm.When using
a 110V/60Hz power supply, the voltage below 83V triggers an
alarm.Once the voltage returns to normal, the alarm will be
automatically cleared.
Reverse Polarity Connection
Emergency Stop
Overvoltage Protection