Operating Light/Sound Features
How to operate the light
The safe you have purchased may include
a long-last LED interior light. Not all safes
include a light.
The batteries that operate the keypad are
the same batteries that operate the light.
If the light in your unit does not turn on,
please change your batteries. Refer to page
5 to change the batteries.
The light will turn on every time you enter your code and will remain on
for 30 seconds. The light duration has three options – off, 30 seconds,
and 60 seconds.
To turn the light off:
Press "0" on the keypad.
1
Press "P" on the keypad.
2
Press "3" on the keypad.
3
To turn the light on for 30 seconds:
Press "0" on the keypad.
1
Press "P" on the keypad.
2
Press "4" on the keypad.
3
To turn the light on for 60 seconds:
Press "0" on the keypad.
1
Press "P" on the keypad.
2
Press "5" on the keypad.
3
NOTE: • If the light duration is 60 seconds, the battery life
will be reduced at a faster rate.
Operating sound features
For Programmable Electronic Lock Only
The tones of the keypad may be turned on and off depending on user
preference.
Turn sound off:
Press "O"on the keypad.
1
Press "P" on the keypad.
2
Press "1"on the keypad.
3
Turn sound on:
Press "O"on the keypad.
1
Press "P" on the keypad.
2
Press "2"on the keypad.
3
6
Bolting Down Your Safe
Bolt-down instructions
Bolt-down kit contents (in select models only):
• 2 lag screws
• 2 gasket washers
• 2 masonry anchors
Tools needed to bolt safe to the floor:
• Drill
• Wrench
• 11mm drill bit – for drilling into the safe
• 7mm drill bit – for drilling into a wood floor
• 13mm drill bit – for drilling into a masonry floor
Warning: • DO NOT drill from any location inside the safe.
• DO NOT bolt through the walls.
Tip the safe onto its right side (door
1
hinges horizontal with the floor).
Unlock the safe and open the door.
2
Turn the safe on its side so the bottom
of the safe is accessible. Using the
11mm bit; drill a hole through two
perpendicular feet on the bottom of
the safe. DO NOT drill from any
location inside the safe.
Tip the safe upright, place the safe in
3
the desired location and open the door.
Use a screw or pencil to mark the floor
4
through both holes.
Move the safe aside to clear both marked
5
spots for drilling.
Drill into the floor:
6
A. For wood: Using the 7mm drill
bit, drill a hole 60mm deep in each
marked spot.
B. For masonry: Using the 13mm drill
bit, drill a hole 60mm deep in each
marked spot. Install
a masonry
F
anchor in each hole.
F
Replace the safe in the desired position, with the holes in the safe aligned with those in the floor.
7
Securing the safe:
8
A. For wood: Pass each lag screw through a washer, then through the safe and into a hole. Tighten with
the wrench.
B. For masonry: Pass each lag screw through a washer, then through the safe and into a masonry anchor.
Tighten with the wrench.
NOTE: • The safe should not be bolted to a wall, this will compromise the fire rating.
Drill holes through the feet only. DO NOT drill through the back or sides.
F
• Bolting/unbolting the unit is at the consumer's expense and discretion.
• SentrySafe / Master Lock is not responsible for any costs incurred if the unit is to be replaced.
F
• When bolting down, ensure the gasket washer is facing down.
• If rubber pads are in place, remove them before drilling.
Not all SentrySafe products come with a bolt-down kit.
Please go to www.sentrysafe.com to learn more about the recommended hardware for your safe.
Troubleshooting
The Problem:
Why it is Happening:
The door will not close and lock.
1. Confirm that there is no obstruction in the
door.
2. Bolted down incorrectly.
After inputting the programmable
1. Battery Power may be low.
code, the door does not open.
2. May be the wrong battery ype.
Red indicator light blinks three
An incorrect code has been entered.
times and there are three beeps.
Red indicator light blinks five
Keypad communication error.
times and there are five beeps.
Red indicator light blinks once and
1. Program button is pressed out of sequence.
there is one beep.
2. 5 seconds has lapsed between button entries.
Red indicator light is blinking.
An incorrect code has been entered three times
and system has entered delay mode.
Yellow indicator light is on.
1. Battery power is low.
2. Battery may be the wrong type.
The Solution:
1. Remove all items and accessories from inside the safe. If
this resolves the issue, re-set the accessories and organize
items to properly fit.
2. See pages 6-7 for proper bolt-down instructions.
1. Use override key to open the safe and replace batteries.
2. Use 9 volt battery to open your safe and replace the
batteries.
Verify code and re-enter. If the programmable code you are
using does not work then use the factory code. If successful
re-program your programmable code.
Contact our customer service
Start over.
Wait two minutes and start over.
Replace with new CR123 lithium batteries.