Herunterladen Diese Seite drucken

Cleco CellTek AC R G1-LD4 Serie Montageanleitung Seite 8

2d reader + gyroscope + tag ubisense

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2
EN
Caution
Danger from laser beams
Eye injury from class 2 laser beam.
► Do not stare into the activated laser
beam.
► Repair any damage immediately. Dam-
age of the optical components can
cause laser radiation.
► Modifications to the barcode scanner
and procedures not outlined in this man-
ual are strictly prohibited.
► Take defective devices out of operation
immediately.
2D Reader: R3
LED light bar, green
4
Installation
Stay Alive: see document P2614MA.
Angle head: see figure see CTBAW(...), page 3.
Pistol: see figure see CTBPW(...), page 3.
Caution
Winding hazard
Unintentional pressing of the start trigger can
cause the drive to turn and cause serious fin-
ger injuries.
► Disconnect the tool from the power sup-
ply when converting work.
Note
Malfunction
Accessories can be initialized incorrectly at
start-up if the tool was not completely
switched off during installation.
► Before installing, remove the battery and
wait approx. 20 seconds for the tool to
stop working.
5
Activating accessories
The accessory is active as soon as it has been installed.
No additional activation is necessary. For further settings,
see the programming manual for the controller and the in-
struction manual for the tool.
► Pressing the start switch starts and ends the rundown
and the angle correction.
6
LED Display
LED Status
Color
Explanation
Ready
Continuous
green light
8
Color
Flashing yellow
light
Continuous
white light
Continuous yel-
low light
Continuous red
light
SA LED
Color
Continuous yel-
low light
TAG LED
Color
Flashing light
yellow
Off
7
Ambient conditions
► Use ESD workstation on installation (Recommenda-
tion).
► Use in environments with EMC Limit Class A (electro-
magnetic immunity for industrial environments).
Features
Operation site
Working tem-
perature
Storage tem-
perature
Type of cooling Convection (self-cooling)
Relative humid-
ity
Working height
Degree of pro-
tection
EN 60529
P2574MA | REV D l 2025-03
Explanation
Initialization.
If more than 20 seconds, see see chap-
ter 8 Troubleshooting, page 9.
Software update is running. Do not in-
terrupt the power supply.
Angle correction is running
(Only modules with G1)
See Troubleshooting Gyro.
(Only modules with G1)
Meaning
Voltage is supplied via the tool holder.
Explanation
TAG active.
TAG not active, see see chapter 8
Troubleshooting, page 9.
Data
Indoors
0 °C – 45 °C
-25 °C – 70 °C
10 % – 90 %, no condensation
Up to 3 000 m (9,843 ft) above sea
level
IP40
Apex Tool Group