8
Troubleshooting
Problem
The product does not start.
The product does not start and the
yellow warning indicator flashes.
The product does not start and the
red warning indicator flashes.
The flow is weak or no flow.
9
Disposal
9.1
To discard the product
● Make sure that you obey local regulations when you
discard the product. Do not burn the product.
10 Technical data
Specification
Rated voltage
Connection
Submersion depth
Particle size
Working pressure
Lifting height
Flow
Water temperature
Min. water level
Residual water level
Pump time 200 l
(1 m lifting height)
Protection rating. pump unit
Protection rating. control unit
Dimensions (HxØ)
Weight
Possible cause
The battery is empty.
The product is not in the water.
The impeller is blocked.
The voltage of the battery is to high.
The product is short circuited.
The water inlet is blocked.
The product is not in water.
Value
18 V
G1"
Max. 2.5 m
Max. 15 mm
0.65 bar
6.5 m
66 l/min
Max. 35°C
10 mm
1 mm
300 s
IPX8
IPX4
19.4 x 13.2 cm
2 kg
Task
Charge the battery.
Put the product in the water.
Clean the suction base.
Use a 18 V battery.
Discard the product.
Remove the blockage from the water
inlet.
Put the product in the water.
EN
SV
NO
PL
DE
FI
FR
NL
9