* If your system has a UV light, plug in the UV power and check to ensure the
Step 10. h.
light turns on when water ows through it. The light has a Flow Sensor Switch that detects
water ow and only turns the light on when needed. If the light does not turn on when
water ows through, check if your power outlet is on, especially when the power is plugged
into the same outlet as another appliance. Typically, a power outlet with a garbage disposal
only has power when the disposal switch is turned on.
Step 10. i.
The water's TDS should be evaluated periodically to verify that the system
performs properly.
Step 10. j.
Check for leaks daily for the rst two weeks after installation to ensure the
system functions correctly. Install the Flood Alarm (optional, model: WD01) for additional
peace of mind and protection.
RO Membrane MC7 Performance & Compliance:
E ciency rating is veri ed by testing per NSF/ANSI 58, Section 6.7.
E ciency rating means the percentage of the system's in uent water available to the
user as RO-treated water under operating conditions that approximate typical daily
usage. System installation must comply with state and local laws.
This RO system contains a replaceable treatment component, critical for e ectively
reducing TDS, and that product water shall be tested periodically to verify that the
system is performing properly.
RCC7 Series conforms to NSF/ANSI 58 for the speci c performance claims as veri ed and
substantiated by test data.
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
This reverse osmosis system contains a replaceable component critical to the system's
e ciency. Replacement of the reverse osmosis component should be with one of
identical speci cations, as de ned by the manufacturer, to ensure the same e ciency
and contaminant reduction performance.