(329IO) MODEL ECO5220/5230 & 6220/6230 SALTWATER SYSTEM WITH E.C.O. ENGLISH 7.5" X 10.3" PANTONE 295U 05/23/2024
TROUBLESHOOTING GUIDE (continued)
LED PANEL
CODE
LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing).
1. Filter pump not attached to system
and/or switch on.
2. Circulation line is blocked.
3. Incorrect inlet and outlet hose direction.
4. Scale on the flow sensor.
5. Flow sensor cord is loose.
6. Inner timer conflict between filter pump
and saltwater system.
7. Flow sensor failure.
1. Dirt or scale on titanium plates.
2. Low salt level / No salt.
3. Electrolytic cell cord is loose.
4. Possible electrolytic cell failure.
1. High salt level.
2. Water temperature > 35ºC.
3. Titanium electrode failure.
1. LED display is off and the "SERVICE"
light is on - the system does not power
up.
2. Caused by high humidity.
3. PCB failure.
If you continue to experience difficulty, please contact our Consumer Service Department for
assistance. See separate "Authorized Service Centers" sheet.
SAVE THESE INSTRUCTIONS
PROBLEM
IMPORTANT
SOLUTION
• Ensure filter pump is attached and operating.
See "Setup Instruction".
• If your unit has plunger valves, ensure that they
are open.
• Clear your filter cartridge and cell from debris and
dirt. See "Maintenance".
• Release all trapped air in the circulation line.
See the filter pump manual.
• Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See "Set
Up Instructions".
• Clean the flow sensor, paying special attention
to the hinge. See "Maintenance".
• Plug the flow sensor firmly into the flow sensor
receptacle.
• Reset both timers on the filter pump and saltwater
system. See "Boost Cycle".
• Contact Intex Service Center.
• Remove primary electrolytic cell for inspection.
Clean it if necessary. See "Maintenance".
• Add salt. See "Salt & Pool Water Volumes".
• Ensure that the cell cord is plugged firmly into the
cell housing receptacle.
• Contact Intex Service Center. Replace the cell if
needed.
• Partially drain the pool and refill it with fresh
water. See "Salt & Pool Water Volumes".
• Contact Intex Service Center.
• Household voltage is too high or too low (+ 20%).
Check the voltage is within the range stated on the
device housing.
• Run the system during midday and avoid running
it during dawn, foggy or raining time. Place a piece
of tile or similar pad, 15" x 15" (38 x 38cm) in size,
between the device and the ground to keep
ground water evaporation away from the system.
• Contact Intex Service Center.
329