(329IO) MODEL ECO5220/5230 & 6220/6230 SALTWATER SYSTEM WITH E.C.O. ENGLISH 7.5" X 10.3" PANTONE 295U 05/23/2024
OPERATION INSTRUCTIONS (continued)
6. Boost cycle
•
First time installation, press and hold "BOOST" button for 5 seconds until
the indicator lights up and the LED display "80". This indicates that the
saltwater system has started more sodium hypochlorite sanitizer
production. You can press and hold the "BOOST" button for another
5 seconds until the indicator is off, which will cancel the Boost cycle.
•
The boost operating hours is 8 times the amount of time programmed into the
system, i.e. if your saltwater system operating time is 2 hours, the boost procedure will run
8 x 2 = 16 hours. After boost procedure has been completed, the system will automatically
switch to the normal working mode.
•
Once the boost is operating, check whether the filter pump operating hours have been set
properly. For example, the boost operating time is 8 hours, the filter pump should be set to
run for 8 hours at least. Increase the filter pump operating time if necessary.
NOTE: If an Intex filter pump is attached to the system, set the pump switch to on "I"
position. During the BOOST mode, periodically test the free chlorine level which should not
exceed the recommended level of 3.0 parts per million (ppm). Do not use the pool if the free
chlorine level exceeds 5.0 ppm.
•
After a heavy rain or if the pool is dirty, press the "BOOST" button to shock the pool again.
7. Stand-by/power saving mode:
•
When the cycle ends, the green "SLEEP" indicator on the control panel
lights up and the LED display flashes "93". The system is now in Stand-By
mode. After a while, it shuts down and sets itself in a Power Saving mode.
The system will automatically turn itself back on in 24 hours, starting its
daily cycle of sodium hypochlorite production.
•
The "SLEEP" indicator stays on, while the system is in the Power Saving
mode. The LED display however, goes blank after 5 minutes. Press any
button (
or
) to view the last LED code.
8. Electrode Self-Clean cycle:
•
Press and hold
button for 5 seconds until the LED display flashes
"10". Depending on your pool water calcium hardness level, press
button again to select the self-clean cycle time as below. Total of
3 settings: 14 hours, 10 hours and 06 hours.
Calcium Hardness
0 - 150 ppm
150 - 250 ppm
250 - 350 ppm
NOTE: The life of the cell varies depending on water conditions, pool usage and operating
time of the device. Select 14 hours cycle time to maximize the life of the electrolytic cell if
the calcium hardness level is up to 150 ppm. Manual routine cleaning and maintenance will
further lengthen the life of the electrolytic cell.
•
With the desired self-clean hours showing, press
the LED display will return to the normal operating time. The system will reverse the polarity
of the electrode (5) every time according to the selected hours.
NOTE: If you forget to lock the keypad controls, the system will automatically lock it.
SAVE THESE INSTRUCTIONS
Self-clean cycle time
Reverse polarity every 14 hours
Reverse polarity every 10 hours
Reverse polarity every 06 hours
button to lock the keypad controls and
329
English
A
Page 18