(329IO) MODEL ECO5220/5230 & 6220/6230 SALTWATER SYSTEM WITH E.C.O. ENGLISH 7.5" X 10.3" PANTONE 295U 05/23/2024
TROUBLESHOOTING GUIDE
PROBLEM
INSUFFICIENT
• Insufficient operating hours of the
SODIUM
Saltwater System.
HYPOCHLORITE
• The salt level in the pool water is less
than 2000 ppm. This is insufficient.
• Sodium hypochlorite loss due to
intense sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
WHITE FLAKES IN
• Excessive calcium hardness is
THE WATER
present in pool water.
NO LED DISPLAY
• No power supply.
• RCD has not reseted.
• A power fuse has blown.
• LED failure.
SAVE THESE INSTRUCTIONS
CAUSE
• Increase the daily Saltwater System operating
• Check the salt level with the Test Kit. Adjust
• Use a pool cover when the pool is not in use
• Remove the cell for inspection, clean it if
• Cover the pool with a pool cover for 2 days
• If the pool is clean and clear, add stabilizer to
• Drain about 20% to 25% of the pool water and
• Find out the switch and turn on.
• Reset the RCD.
• Contact Intex Service Center.
SOLUTION
time. See "Operating Instructions".
as needed. See "Salt & Pool Water Volumes".
and/or when the unit is operating.
necessary. See "Maintenance".
with the device running and then test the water
using the test strips.
the water and then test the water with the
device running.
add fresh water to decrease the calcium
hardness. Inspect the electrolytic cell for scale
buildup. Clean the electrolytic cell if necessary.