Herunterladen Inhalt Inhalt Diese Seite drucken

Scholtes TRP 632 TD L Bedienungsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für TRP 632 TD L:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 51
1. Use a suitable supply cable, H05RR-F or higher, with
the right dimensions (cable cross section: 25 mm).
2. To open the terminal board, use a screwdriver as
a lever under the side tabs of the cover (see Terminal
board picture).
3. Loosen the cable clamp screw and the terminal
board screws in accordance with the type of
connection required and position the connection
supports as shown in the following table and diagrams.
4. Position the wires in accordance with the information
given in the following table and diagrams and connect
the appliance by tightening all the screws for the
springs as much as possible.
Voltage and
Electrical connections
mains frequency
400V 3-N ~
50/60 Hz
5. Secure the power supply cable by fastening the
cable clamp screw, then put the cover back on.
Phase
Phase
Neutral
U-bolt
Earth
connection support
Fase
Cavallotto
Fase
Fase
Neutro Terra
Connecting the electricity supply cable to the mains
If the appliance is being connected directly to the
electricity mains an omnipolar switch must be installed
with a minimum opening of 3 mm between contacts.
!
The installer must ensure that the correct electrical
connection has been made and that it is fully compliant
with safety regulations.
Before connecting the appliance to the power supply,
make sure that:
• The appliance is earthed and the plug is compliant
with the law.
Terminal board
Three-phase 400
Phase
Three-phase 400
Three-phase 400
• The socket can withstand the maximum power of
the appliance, which is indicated on the data plate
located on the appliance itself.
• The voltage falls within the range of values indicated
on the data plate.
• The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
Once the appliance has been installed, the power
!
supply cable and the electrical socket must be easily
accessible.
!
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
!
by authorised technicians only.
!
The manufacturer declines any liability should
these safety measures not be observed.
! Do not remove or replace the power supply cable
for any reason. Its removal or replacement will void
the warranty and the CE marking. INDESIT does not
assume liability for accidents or damage arising from
replacement/removal of the original power supply
cable. Replacement can only be accepted when
carried out by personnel authorised by INDESIT and
using an original spare part.
GB
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis