1. Heater should be thoroughly inspected before each use, and by a
qualified service person at least annually. If relighting a hot heater,
always wait at least 5 minutes.
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or
wear. Suspected areas should be leak tested. If the hose leaks, it must be
replaced prior to operation. Only use the replacement hose assembly
specified by manufacturer.
3. The pressure regulator and hose assembly supplied with the appliance
must be used. Replacement pressure regulators and hose assemblies
must be those specified by the appliance manufacturer.
Lighting:
Note: This heater is equipped with a pilot light that allows for safer startups
and shutdowns. Pilot must be lit before main burner can be started.
1. Turn the control knob to the "OFF" position.
2. Fully open propane cylinder valve.
3. Push control knob in and rotate to pilot position (Figure 1).
Note: For initial start or after any cylinder change, press control knob for at
least 1 minute to purge air from gas lines before proceeding.
4. Push and release the igniter button until pilot flame is visible through the
glass tube.
5. Once the pilot is lit, continue to depress the control knob for 30 seconds.
- 24 -