COMMON PROBLEMS

Low battery
power supply
Damaged
refrigerant
hose or valve
stem
Failure of
refrigerant
filling
Potential
leak points
The instruments has low power sign. When it is displayed , it
means the battery power is insufficient. At this time, the battery
should be replaced as required in order to avoid affecting
normal use.
Please check the pipe fittings and the hoses before testing.
Once any damage is found , please replace it immediately to
avoid improper use or any accident occurring.
There is a valve core in the refrigerant inlet of the refrigeration
system. When connecting the instrument, pay attention to the
two terminals of the hoses. Connect one terminal with a core to
the refrigeration system, while another terminal without a core
to the instrument.
Every hose terminal comes with a nylon pad that is limited a
certain life of using. Over use or other situation will make it
defective, which result in leakage.
The instrument refrigerant inlet (the middle port of the instru-
ment) has a port with valve core, which is used to vent the air
in the hoes after connecting the refrigerant to the instrument.
The port is equipped with a copper plug screw. It is required to
tighten it every time before or after operation.
Check the refrigeration system's pipes and connectors.