Herunterladen Inhalt Inhalt Diese Seite drucken

Power Supply Maintenance; Electronics Maintenance - Stocker Geyser Pro Benutzerhandbuch

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Art. 415 – Geyser Pro
Swelling or hardening (especially in the presence of chemicals)
Losses
Discoloured or damaged sections
If necessary, replace the entire compromised section. Annual replacement is
recommended for sections most exposed to liquids.
Checking and Maintenance of Fittings
Check quick couplings and non-return valves:
Check for leaks.
Check for tightness and correct orientation with respect to flow.
Clean up any residual liquid or limescale.
System Pressure Control
After each maintenance, carry out an operational test of the system to
Check that all nozzles atomise correctly.
Ensure that the minimum pressure of 3.5 bar is maintained throughout the line.

6.2 Power Supply Maintenance

Proper power management is essential for the smooth operation of Geyser Pro, whether in
battery or mains-powered mode.
Charge batteries regularly, avoiding storing them completely discharged, especially
during long periods of inactivity
Visually check the mains adapter at regular intervals for damage, wear or signs of
malfunctioning

6.3 Electronics Maintenance

The electronic components of the Geyser Pro are designed to operate safely without requiring
frequent intervention. However, it is important to observe a few basic precautions:
The control board is sealed and must not be opened, except in case of malfunction and
only by qualified personnel
Absolutely avoid introducing liquids into the control area to prevent short circuits or
irreversible damage to the system