• Unscrew the drain cover and remove the drain plug. Drain all the residual water
into a drip tray or swivel the appliance slightly backwards to direct the water into
a suitable container.
• Leave the appliance running in FAN mode (ventilate) for half a day in a warm and
dry room to prevent mould from forming in the appliance.
• Switch off and unplug the appliance, wrap the power cable around the cable
holder and replace the drain plug and cover.
• Dismantle the exhaust air hose and store it.
• Remove the batteries from the remote control.
• Cover the appliance with a plastic film. Store the air conditioner in a clean, dry
and dust-free place, out of the reach of children.
Compressor delay protection
To protect the compressor, there is a delay of three minutes between each time the
appliance and compressor are switched off and switched on again - except when the
appliance and compressor are switched on for the first time using the on/off switch.
SAFETY FUNCTIONS
Anti-freeze protection
If the temperature of the internal lines drops too low, the appliance pauses. The display
shows "E4" and the appliance activates the anti-frost protection, which deactivates all
buttons on the control panel except the on/off button. As soon as the temperature of the
internal lines rises above 8°C (46.4°F) again, the anti-frost protection is deactivated and the
appliance returns to the selected settings.
USEFUL INFORMATION
We do everything we can to ensure that our products are easy to install and use. However,
should you encounter any problems, here are some troubleshooting tips that may help you
solve the problem.
If the problem persists, please contact our customer service team at service-
home@schuss.at
STORAGE
S. 168

Werbung

loading