Turning off/on the Zero-Radiation-Function (ZRF)
Activating the Zero Radiation Function makes the baby
units stop transmitting signals to the parent unit in standby
mode. Radiation = Zero. In standby mode (when the mi-
crophone in baby unit is not detecting sound), you will not
see temperature or battery status from the baby unit that has
activated ZRF. Although, this information will be displayed
when the baby is making sound because the information
then will be transmitted together with sound signal.
NOTE: When the ZRF is activated, the out-of-range
alarm will be deactivated. For this reason, only use the
ZRF when you know that the units are within range.
The baby and the parent unit must be turned on and connect-
ed to each other.
Parent unit: Press and hold the "M" key for 2 seconds.
1
SLEEP TIMER will appear steady and ON or OFF will
be flashing in display.
Parent unit: Press the "M" button two times. The
2
display changes from SLEEP TIMER to ZRF.
Parent unit: Use the "+/-" buttons to turn the Zero
3
Radiation Function on or off. If you activate ZRF, the
ZRF icon will appear in both baby and parent unit
display.
Parent unit: Press the "M" button to confirm your
4
choice.
Repeat step 3 and 4 if there are more than one baby unit
connected to parent unit.
Parent unit: Press the "M" button three more times to
5
return to standby mode.
Alarms / Warnings
OUT-OF-RANGE alarm/alert is activated after 30 seconds
when:
baby- and parent unit is beyond communication range
1
baby unit is turned off
2
baby unit's power is suddenly cut off (battery com-
3
pletely empty).
An alarm will be heard, LCD-display will show OUT OF
RANGE and LCD-light will flash.
TEMPERATURE alarm/alert is activated if
the actual temperature exceeds the selected tempera-
1
ture high limit.
the actual temperature goes below the selected low
2
temperature limit.
An alarm will be heard, LCD-display will show TEMP
ALARM and actual temperature will flash together with
HIGH or LOW.
LOW BATTERY alarm/alert is activated if
the baby unit's battery power level falls below a
1
certain limit.
he parent unit's battery power level falls below a
2
certain limit.
An alarm will be heard and the battery status indicator (of
either baby or parent unit) will flash and LCD-display will
show BATTERY POWER LOW.
SMOKE alarm/alert is only working if the smoke detector
accessory is purchased. If smoke is detected an alarm will be
heard and LCD-display will show SMOKE.