WE2111, Command Descriptions
A3953-1.0 en/de
Permissible termination characters are ';' (ASCII 59), LF
(ASCII 10), crlf (ASCII 13 10), LFCR (ASCII 10 13). E.g.
ADR?; is the same as ADR? crlf.
The WE2111 always uses crlf as the termination of its
responses.
3.5
Initial sequence to start
communication
The first command to the WE2111 should be the select
command Sxx. This should be sent even if only one unit
is connected.
Tip
S99; will select all connected indicators.
3.6
Trade Counter
The WE2111 does not check to see if new data is
different from the old data before incrementing the trade
counter, so sending IAD1,6000 will increment the counter
even if the WE2111 is setup with a fullscale of 6000 kg
already.
Query the trade counter with command TDD?.