Herunterladen Diese Seite drucken

Dustcontrol S34000 EX Montageanleitung Seite 36

Vorschau ausblenden Andere Handbücher für S34000 EX:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
Troubleshooting
Problem
Filter-cleaning does not
There is no compressed air.
work.
Wrong control voltage.
The vacuum producer is
The dust separator is not connected to the vacuum
running but nothing is be-
producer.
ing sucked into the sys-
There is no collection device connected to the dust
tem.
separator.
The collection device is not connected tightly to the
dust separator.
The vacuum producer rotates in the wrong direction.
The explosion valve has been triggered.
The vacuum producer is
Leaking hoses or a leaky tubing system.
running but the suction is
Clogged filters.
weak in the system.
The tubing system is blocked.
The explosion valve has been triggered.
The unit is blowing out
Filter is loose or broken.
dust.
*When restoring the explosion valve, the operation of the installation should be checked and any damaged
components replaced. Filters should always be changed when restoring. Once this is fixed, the unit and system can
be
S34000 EX
Cause
Check the piping system and associated vacuum manu-
facturer.
Verify that the voltage is 24V.
Connect the tubing system between the dust separator
and the vacuum producer.
Connect a collection device (plastic sack or container)
Make sure that the collection device is connected tightly.
Get an electrician to change the phase.
Repair or change to new explosion valve.
Fix this.
Clean or replace the filter(s) (see Filter Replacement).
Check for blocks and remove them.
Repair or change to new explosion valve.
Remedy according to filter change above.
36
Action

Werbung