Troubleshooting

Caution
Any disassembly, repair or alteration of the product is forbidden, except for a qualified technical personnel. (It may cause dangerous fire or
electric shock) When a failure happens during operation, please find out the solution corresponding to the cause listed below. Contact after-sale
department of our company if you fail to get the product back to normal operation.

Power supply

Phenomenon
The toilet doesn't operate
Washing, Bidet
Phenomenon
The nozzle don't spray
Weak water pressure
Water supply failure during operating
Water temperature is not high enough
Drying by warm air
Phenomenon
Low air temperature
No air blowing
Seat heating
Phenomenon
Too low temperature
Cause
Power failure
Toilet is not switched on
Cause
No water supply available
Water tap is closed
Nozzle opening is jammed with something
The pressure is set at low level
Water intake is blocked
Time limit for the function has end up
Sensor failure
Toilet is in "no-heating" mode
Cause
Toilet is in "no-heating" mode
The function has ended
Toilet is in "energy saving" mode
Cause
Toilet is in "no-heating" mode
Toilet is in "energy saving" mode
Solution
Check the fuse
Turn on the toilet
Solution
Don't perform washing function until water supply
is available
Open the tap
Clean the nozzle
Raise the pressure
Clean up the filter
Restart the function
Take proper position when sitting on seat to ensure
the sensor works well
Set water temperature higher
Solution
Set air temperature higher
Restart the function
Take proper position when sitting on seat to ensure
the sensor works well
Solution
Set seat temperature higher
Take proper position when sitting on seat to ensure
the sensor works well