Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Building Dryer
BT 700

7. Troubleshooting

WARNING: Maintenance work must be carried out with the device turned off, i.e. with the mains
plug pulled out.
Display C
PROBLEM:
0101
none
rHxx
none
Decy
None
Full
Alarm 1
Lo t
Alarm 2
Lo t
Alarm 3
LOPt
Alarm 4
Hi T
Alarm 5
Hi T
Alarm 6
Prob
Alarm 7
Pro1
Alarm 8
Pro2
Alarm 8
Pro3
Alarm 8
LOPS
Alarm 9
HIPS
Alarm 10
Punp
Alarm 11
Person executing: B - User, AST - authorised service technician
Contact your local dealer or the HEYLO customer services department for spare parts
and service. We would be glad to assist you!
Your HEYLO customer services
Tel.
+49 (0) 42 02 – 97 55 15
Fax
+49 (0) 42 02 – 97 55 97
E-mail: service@heylo.de
CAUSE
After plugging in the mains
plug, the software version is
displayed
Display of relative air humidity
Device in defrosting cycle
Condensation tank is full
Defrosting failed
Surrounding temperature
under 1° C
Temperature difference is too
low
(Thawing point is not reached)
Surrounding temperature
above 36° C / humidity < 75%
rH
Surrounding temperature
above 30° C / humidity < 78%
rH
Wet sensor U.R. outside
nominal value
Temp. Sensor Evaporator T1
Temp. Sensor Evaporator T2
Temp. Sensor Room Temp T3
Low pressure alarm
High pressure alarm
opt. Pump without function
26
Perso
Solution
n
execu
ting
Display will go off after approx.
4 seconds
Device will start on its own after
max. 8 min
B
Empty the tank and put it back
in again
B
Pull out the mains plug and
after 10 seconds Switch it on
again
B
Place the device in a room at
>10° C for 30 seconds
Alarm is automatically reset
B
Device starts automatically
after 210 seconds. After 3
interruptions, reset with buttons
3+4 (press for 10 seconds).
B
Automatic start when
temperature is < 35° C
B
Automatic start when
temperature is < 30° C
B /
Device continues to run. If the
AST
error occurs repeatedly, contact
Service
AST
Contact HEYLO Service
AST
Contact HEYLO Service
AST
Contact HEYLO Service
not active
not active
B/AS
Clean pump
T
Contact HEYLO Service
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis