Verfügbare Sprachen

Button 1
"ON/OFF" - Switching on and off function
By pressing the "POWER" (OPERATION) button the machine is switched from an ON
state to an OFF state and the other way round.
Button 2/3
"HUMIDITY SET"
Press the arrow keys up or down at the setting "SET %" (setting in %) to either
increase or decrease the required humidity setting.
When first pressing on one of the two buttons, the display changes from the reading
mode to the set mode for humidity and when further pressing the respective button the
air humidity setting is either increased or decreased.
Button 4
"HOUR COUNTER" - job hour counting function
When pressing the "HOURS" button the number of operating hours of the compressor
until that point appears for a few seconds on the display.
"RESET" If you press the button with the device turned off for 4 seconds, the job hour
counter is set to 0
"HOUR COUNTER" - total hour counting function:
When pressing button 4 (Hours) + button 3 (SET) the number of total operating hours
of the compressor appears for a few seconds on the display.
Button 5
Optional condensation pump:
If the condensation pump is connected (optional) it can be controlled manually with
button 5. This should take place for testing or before dismantling the device.
(For activation see below, additional functions)
Display A
(POWER)
The "POWER" display lights up green when the device is switched on
Display B
(ALARM)
The display B lights up red if there is an interruption or an alarm signal.
(also see list of faults, point 7)
Display C
(Display)
When power is being supplied, (plugging in the mains plug) for about
4 seconds, Display C shows the version number of the electronics software (e.g. 0100)
See the table for further displays:
Action
none
Pressing buttons 2 or 3
None
Pressing button 4
none
Display
Significance
rH xx
Display of actual air humidity
Target value of humidity regulation
Cont
Permanent dehumidification
rH xx
Hygrostat operation
Full
Condensation tank is full
Xxxx
Display of operating hours in h
Defr.
Automatic defrosting is active
21