4. Operating the building drier

Only let the building drier function in an upright position.
Connect to an appropriately earthed socket with the correct voltage and 16A
protection.
Check whether it is ready to operate
Read the operating hours counter and if possible document the status
Read KW/h counter and if possible document the status. (Reset of the hours is
only possible when switched off.
Check whether the condensate tank is being used correctly.
Press the power button (1) to switch on (Display A lights up green)
ATTENTION the blinking Display D indicates a pause of up to 210 sec
(compressor delay)
If lamp D is off, the set degree of moisture has been reached.
After the delay period, the device starts to run on its own.
The desired degree of moisture can now be set with buttons 2 and 3.
Control panel
1
Operating and display elements/Explanation of additional functions
Position
Description
1
"POWER" button
2
"SET" button
3
"SET +" button
4
"HOURS" button
5
"PUMP" button
A
"POWER" display
B
"ALARM" display
C
"Display" indication
D
"RUN" display
E
"FULL" display
F
"REMOTE" display
A
B
2
Function
Start button (On/Off)
Setting of parameter (minus)
Setting of parameter (plus)
Display of operating hours
Manual pumping off with an optional pump
Display of the operating status (on or off)
Indication of error when an alarm is sounded
Display of the selected parameters and the
operating status
Display of operating or pause periods
Display when the condensate tank is full
Display during operation with optional external
hygrostat