Building Dryer
BT 700
Display D
(RUN) (Display is only active when device is running)
If the display is off, the device is pausing (e.g. it has reached the set air humidity). If
the display is blinking, the device is under compressor delay after switching it on
(lasts up to 210 seconds) or it is in a defrosting phase.
Display E
(FULL)
Display E lights up red when the condensation tank is full.
Display F
(REMOTE)
When the "REMOTE" function (controlling the device through the external hygrostat)
is activated, the "Remote" display lights up

Additional Functions

Using a condensation pump
If an optional condensation pump is used, it must be fitted in the tank and connected
to the pump connection in the tank room.
Condensation pump, Art. No. 1760092
Press button 5 and button 3 together until the tank FULL display E lights up for 0.3
seconds to activate the pump function. PUMP appears on the display. The pump is
now active, the FULL display blinks every 10 seconds.
Using an external hygrostat:
"Remote" Function (remote control element): An external hygrostat can be connected
to the device. It must be set on the control panel for this purpose:
Hygrostat Art.-No.: 1110552