8. Troubleshooting

WARNING: All maintenance work listed below is to be performed with the unit switched
off and the power plug pulled.
PROBLEM
Unit does not start
Compressor
does
not
start
Blower wheel does not
run
Humidifier functions,
however the room does
not dry
Ice or moisture only on
one part of the cooling
coils
No moisture or ice on the
cooling coils
Unit
permanently
defrosting
Unit does not defrost
Unit collects minor water
quantities
Unit does not drain
U – User
HS – HEYLO Service
For spare parts and service, please contact or local dealer or HEYLO Customer
Service. We are here for you!
Your HEYLO Customer Service:
Tel.
+49 (0) 42 02 – 97 55 15
Fax
+49 (0) 42 02 – 97 55 97
Email service@heylo.de
CAUSE
No voltage at the system
Switch not switched on
The unit requires 5 minutes prior
to restarting.
Overload prevents starting.
Faulty or broken wire
Defective relay
Compressor does not run
Unit is in the middle of defrosting
Blower blocked
Loose or broken wire
Faulty blower motor
Not enough time for drying
Insufficient air movement
Intake of (outside) air too large
System may be leaking
Low system filling
Temperature or air humidity too
low
System may be leaking
Refrigeration system damaged
Compressor does not run
Room temperature too low
Defective regulator
Defective defrosting unit
Defective regulator
Room too dry
Room temperature too low
Air flow through the unit limited
Check pump for possible faults
Pump defective
Condensate hose clogged
Performed
Solution
by
U
Connect unit to the power socket; verify, if
socket is live.
U
Switch on the switch
U
Switch unit off, wait 5 minutes, restart.
U
Lower room temperature to below 38 ° C.
HS
Replace or repair broken / loose wire.
Check relay using voltmeter/ ammeter
HS
Contact your dealer or HEYLO service
HS
center.
Wait approx. 15 minutes
U
Remove blockage
HS
Replace broken wire
HS
Replace blower motor
U
Allow more time for drying
U
Increase air movement using HEYLO turbo
dryers
U
Reduce air inflow into the areas to be dried.
HS
Search for leak using a gas detector.
HS
Repair and refill system.
U
Measure
HEYLO MMS plus
HS
Search for leak using a gas detector
HS
Check compressor
HS
Contact your dealer or HEYLO service
center
U
Increase room temperature.
HS
Replace regulator
HS
Replace defrosting unit
HS
Replace defrosting unit
U
Determine air humidity using a hygrometer.
U
Increase room temperature.
U
Increase air flow, clean filter and coils.
HS
Clean pump and replace defective parts as
needed
HS
Replace pump
U
Replace condensate hose