Installation
Make sure you take all the necessary precautions to
guarantee proper installation in compliance with the
applicable norms in force regarding accident-prevention
for electrical connection. For the correct operation of the
appliance when built into the cabinet, it is vital that the
minimum distances illustrated in fig. 3 be respected.
The hob features a type Y degree of protection against
overheating in compliance with norm EN60335-2-6. All
surfaces adjacent to the cabinet and the back panel
should be made of materials resistant to a temperature
of 65°C.
Fixing to the unit
To fasten the hob to the cabinet, carry out the following
steps (fig. 4):
• screw the 2 screws "A" (provided with the appliance)
to the cabinet, allowing the screw heads to protrude
approx. 2 mm from the wood;
• hook the hob to the 2 screws "A" and push it
backwards;
• fasten the hob to the cabinet at the back using the 2
flanges "B" and the 4 screws "C" provided with the
appliance.
Gas supply connection
• Check that the appliance is set for the type of gas
available and then connect it to the mains gas piping
or the gas cylinder in compliance with current
regulations and standards.
• This appliance is designed and set to work with the
gas indicated on the label situated on the actual hob.
If the gas supply is other than the type for which the
appliance has been set, proceed with replacing the
corresponding nozzles (provided), following instruc-
tions given in the paragraph "Adaptation to different
types of gas".
• For trouble-free operation, suitable use of energy and
longer life of the appliance, make sure that the supply
pressure complies with the values indicated in the
table 1 "burners and nozzles specifications, otherwise
install a special pressure regulator on the supply pipe
in compliance with current standards and regulations.
• Connect in such a way that the appliance is subjected
to no strain whatsoever.
Either a rigid metal pipe with fittings in compliance with
the standards in force must be used for connecting to the
nipple union (threaded ½"G male fitting) situated at the
rear of the appliance to the right (fig.5), or flexible steel
pipe in compliance with the standards in force, which
must not exceed 2000 mm in length.
Should it be necessary to turn the fitting, the gasket
(supplied with the appliance) must be replaced.
Upon completion of installation, check the gas circuit,
the internal connections and the taps for leaks using a
B C