The following instructions are provided for qualified installers
so that they may accomplish installation, adjustment and
technical maintenance operations correctly and in compliance
with current regulations and standards.
Important: the appliance should be disconnected from
the mains electricity supply before any adjustment,
maintenance, etc. is carried out. Maximum caution should
be used should it be necessary to keep the appliance
connected to the electricity supply.
The appliance has the following technical specifications:
Class: 1
The dimensions of the appliance are given in the figure on
page 2. For trouble-free operation of appliances installed in
housing units, the minimum distances shown in fig.10 should
be observed. Adjacent surfaces and the wall at the rear should
also be able to withstand an overheating temperature of 65 °C.
On the lower part of the stove there are 4 adjustable feet with
a screw which will allow you to level the stove when necessary.
It is essential for the appliance to be level. Warping caused by
bad positioning could alter the characteristics and performan-
ce of the appliance itself.
fig.6
ELECTRICAL CONNECTION
THE APPLIANCE MUST BE EARTHED
The hob is designed to work with alternating current at the
supply voltage and frequency indicated on the data plate
(situated on the bottom part of the appliance or on the last
page of the instruction booklet). Make sure that the local supply
voltage corresponds to the voltage indicated on the data plate.
The hob is not fitted with a power supply cable, as the cable
should be sized according to the type of electrical connection
in use (see connection diagram below). Use a H05VV-F rubber
cable.
Open the terminal board following the instructions on the
diagram opposite:
To install the power supply cable, proceed as follows:
• Unscrew the wire clamp screw "V" and the contact screws
(fig. 11).
• Fasten the small cables beneath the screw heads according
to the diagram below.

INSTALLATION

• Fasten the supply cable in place with the clamp and close
the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated
on the data plate. When connecting the cable directly to the
mains, install an omnipolar switch with a minimum contact
opening of 3 mm between the appliance and the mains. The
omnipolar switch should be sized according to the load and
should comply with current regulations (the earth wire should
not be interrupted by the switch). The supply cable must be
in such a position that no part of it can reach a temperature
of 50°C above room temperature. Before connecting to the
power supply, make sure that:
• The limiter valve and the domestic system can withstand
the load from the appliance (see data plate);
• The mains are properly earthed in compliance with current
directives and regulations;
• There is easy access to the socket and omnipolar switch,
once the hob has been installed.
Electrical
connection
*Application of the simultaneousness coefficient in accordance with
norms.
OVEN TECHNICAL SPECIFICATIONS
Voltage and Frequency 230/400V ~ 50 Hz
Power Max: 10 kW
11
2
1
2
1
3
4
5
V
Power supply
voltage
230V -1+N ~ 50Hz
400V 2+N ~ 50Hz
400V -3+N ~ 50Hz
230V -2 ~ 50Hz
230V -3 ~ 50Hz
230V -2+2N ~
50Hz
fig.7
Cross
Fuse
section
32* A
4 mm²
32 A
4 mm²
25 A
2.5 mm²
32* A
4 mm²
25 A
2.5 mm²
25* A
2.5 mm²