• Instruction manual x 1
• Aluminium tube x 1
• HEPA filter x 1
• Connector x 1
DESCRIPTION OF THE GRAPHIC PAGES
A. Hoover components
1.
Central unit
2.
Carrying handle
3.
Power switch
4.
Tank lid
5.
Suction hose connection
6.
Reservoir
7.
Suction hose
8.
Aluminium tube
9.
Buckle lock
10.
Battery lock
11.
Battery
12.
Buckle
B. Removing the battery
1.Battery lock
C. Switching the hoover on/off
1.Vacuum cleaner switch
D. Closing the lid
1.Vacuum cleaner handle
2.Cover locks
E. HEPA filter
F. Hose assembly
1.Suction hose connection
2.Tank socket
G. Installation of suction hose
H. Dacron type filter
I. Fitting the aluminium end
1.Hose end
2.Aluminium tube
J. Removing the hoover handle
USE
INSTALLING THE BATTERY
• Always switch off the unit before installing or removing the battery .
• Hold the purifier and battery pack firmly when installing or removing
the battery pack. Holding the purifier and battery pack insecurely
may cause them to slip.
• To remove the battery, slide it out of the unit while pushing the button
on the front of the cartridge.
• To install the battery pack slide it into place. Insert it all the way until
it locks into place with a slight click.
CHARGING
The battery is supplied in a partially charged state. The battery
should be charged in conditions where the ambient temperature is
+0⁰C to 50⁰C. A new battery or one that has not been used for a
long period of time will reach full power capability after
approximately 3 - 5 charge and discharge cycles.
The battery fixing button is used to release the battery lock on the
device.
The battery should not be charged for more than 8 hours.
Exceeding this time may damage the battery cells. Avoid
consecutive short charges. Do not recharge batteries after
short use. A significant decrease in the time between
necessary charges indicates that the battery is worn out and
should be replaced.
Batteries become warm during the charging process. Do not
undertake work immediately after charging - wait until the
battery has reached room temperature. This will prevent
damage to the battery.
BATTERY CHARGE STATUS INDICATION
The battery is equipped with a charge status indication (3 LEDs). To
check the battery charge status, press the battery charge status
indicator button (2). When all LEDs are lit, the battery charge level
is high. Lighting of 2 LEDs indicates partial discharge. The fact that
only 1 diode is lit indicates that the battery is exhausted and needs
to be recharged.
ON AND OFF
Always set the power switch to the "O" side when you are not using
the hoover for a long time. (Fig.A-3)
• To start the tool, press the power switch down towards the "I(ON)"
position.
• To stop the tool, press the power switch down towards the "O(OFF)"
position.
MOVING THE HOOVER
Always ensure that the tank lid is firmly locked with the clamps
before moving the tool.
When moving the unit, carry it by holding the handle on the head.
(Fig.A-2)
REPLACEMENT OF HEPA FILTER UNIT
Always check that the powder filter is correctly installed
before using the unit. If it is not properly installed, dust will enter
the motor housing and cause the motor to fail. (Fig.E)
To remove the
HEPA
filter assembly, perform the following steps:
• Pull up the clamps on both sides of the tool to release them.
• Pull forward slightly to fully unlock the two buckles
• Separate the head assembly from the tank and completely clean the
dust from the tank
• Pull a little firmly forward to separate the powder filter assembly and
tap it lightly to remove the dust or replace it with a new one. If the
dust is difficult to remove, you can use a blower to remove it
• To install the HEPA filter unit, follow the removal procedure in
reverse order
CONNECTING OR DISCONNECTING THE SUCTION HOSE
• Always ensure that the suction hose is securely fastened. Failure to
do so may result in accidental injury.
• Never bend or move the unit by the suction hose. Pulling the
suction hose may cause it to break or deform.
• To connect the suction hose, insert one of the suction hose
connections into the tank mounting port and turn it clockwise until it
locks in place
• To disconnect the suction hose, follow the assembly procedure in
reverse order (Fig. F,G)
CONNECTING OR DISCONNECTING THE ALUMINIUM TUBE
• To connect the aluminium tube, insert one end of the tube into the
other suction hose connector until it locks into place
• To disconnect the aluminium tube, pull it out a little firmly directly
(Fig.I)
MOUNTING OR DISMOUNTING OF THE TRANSPORT BRACKET
• To fit the carrying handle. Loosen the two screws by turning them
counterclockwise with a screwdriver.
• To uninstall the carrying handle, follow the assembly procedure in
reverse order (Fig.J)
OPERATION OF THE DEVICE
• Check that the power switch is off (in position 0).
• Check that the powder filter unit has been installed in the unit.
• Check that the tank lid is firmly locked by the clamp.
• Connect the suction hose to the machine.
• Connect the aluminium tube to the suction hose connector.
• Move the tool to the area where you will be doing the cleansing.
• Set the power switch to position I to start the tool and move the
aluminium tube forwards or backwards to collect the dry dust
CONSERVATION
• To maintain the SAFETY and RELIABILITY of the product, repairs,
any other maintenance or adjustments should be carried out by an
AUTHORISED SERVICE.
CLEANING THE HEPA FILTER UNIT
• After using the hoover several times, wash the HEPA filter in water,
rinse thoroughly and dry in the shade before use. HEPA filters
should never be washed in a washing machine.
• Do not rub or scratch the HEPA filter with hard objects such as a
brush.
• HEPA
filters wear out over time. It is recommended to have several
parts
CLEANING THE APPLIANCE
• Occasionally wipe the outside (purifier housing and tank) of the
purifier and the inside of the tank with a cloth dampened in soapy
water.
• Also clean the suction fitting of the tank
7