Herunterladen Diese Seite drucken

BWT ROBUST MINI Installation Und Betriebsanleitung Seite 12

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS ECOSOFT ROBUST MINI,
ROBUST 1500, ROBUST PRO, ROBUST COFFEE, ROBUST 3000, ROBUST 3000MAX, ROBUST 4000
12
2. SPECIFICATIONS AND COMPONENTS
2.1 TECHNICAL SPECIFICATIONS
Parameter
Purified water
flow rate, l/h
Feed water flow
rate, L/h
Concentrate flow
rate, L/h
Inlet water
pressure, bar
(MPa)
Operating
pressure, bar
(MPa)
Feed water
temperature, °С
Ambient air
temperature, °С
Connection to
water mains
Overall
dimensions,
H × W × D, mm
Weight, kg, max.
Electrical rating
Power
consumption, W,
max.
Ingress protection
rating
At feed water TDS of 250 ppm and temperature of feed water of 25 °С, ±10%.
1
If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it. If
2
water pressure exceeds the upper limit, install a pressure regulator before the RObust.
Using the RObust with feed water temperature between +20 and +30 °С produces a lower rejection rate and
3
higher flow rate, which yields higher TDS of purified water. Using the system with feed water above +30 °С is
advised against.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2024
RObust MINI
RObust 1500
55–60
90–100
1
110–125
160–175
55–65
2,0–5,0
2,0–6,0
(0,2–0,5)
(0,2–0,6)
2
5,0–7,0 (0,5–0,7)
570x386x195
417x362x300
6
9
100–240 V, 50–60 Hz
72
120
Value
RObust PRO
RObust 3000
RObust COFFEE
70–75
130–140
1
1
140–150
280–340
70–75
150–200
2,0–5,0
(0,2–0,5)
2
2
+4...+30
+5...+40
"
½
10
72
IP 54
RObust 3000MAX
150–160
1
1
250–300
100–140
2,0–6,0 (0,2–0,6)
7,0–8,0 (0,7–0,8)
3
3
466x522x403
25
180–240 V, 50–60 Hz
250
RObust 4000
150–180
1
230–300
80–120
2
553x195x562
120

Werbung